Siemens RUGGEDCOM ROX II User Manual page 314

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 8
Layer 2
switch lm1 1
auton
on
speed
auto
duplex
auto
switchport
no flow-control
no alias
rate-limiting
no ingress-limit
no egress-limit
!
port-security
no shutdown-time
no admin-shutdown
dot1x
no reauth-enable
!
!
lldp
no notify
!
mcast-filtering
no gmrp
!
cos
no inspect-tos
!
vlan
pvid 1
no gvrp-mode
!
spanning-tree
no restricted-role
no restricted-tcn
!
!
.
.
.
Section 8.1.2
Configuring a Switched Ethernet Port
To configure a switched Ethernet port, do the following:
1.
Make sure the CLI is in Configuration mode.
Navigate to interface » switch » {slot} » {port}, where {slot} is the module and {port} is the switched
2.
Ethernet port.
3.
Configure the port settings by configuring the following parameter(s) as required:
CAUTION!
Security hazard – risk of unauthorized access and/or exploitation. Switched Ethernet ports are
enabled by default. It is recommended that ports that are not in use be disabled. Unused ports, if
not configured properly, could potentially be used to gain access to the network behind the device.
CAUTION!
Configuration hazard – risk of data corruption. Changing a switched Ethernet port from switchport
mode to dedicated routing mode will automatically change any configuration elements that
268
RUGGEDCOM ROX II
CLI User Guide
Configuring a Switched Ethernet Port

Hide quick links:

Advertisement

Table of Contents
loading