Chapter 13
Unicast and Multicast Routing
Parameter
is-type { is-type }
metric-style { metric-style }
area-authorization { area-authorization }
area-password { area-password }
area-authentication { area-authentication }
domain-authorization { domain-
authorization }
domain-password { domain-password }
domain-authentication { domain-
authentication }
4.
Add one or more Network Entity Titles (NETs). For more information, refer to
Network Entity Titles
5.
If necessary, configure intervals for the generation of Link-State Packets (LSPs). The default is 30 seconds. For
more information, refer to
6.
If necessary, configure refresh intervals for Link-State Packets (LSPs). The default is 900 seconds. For more
information, refer to
7.
If necessary, configure the minimum interval between consecutive SPF calculations. The default is 1 second.
For more information, refer to
8.
If necessary, configure how long LSPs can reside in the device's Link State Database (LSDB) before they are
refreshed. The default is 1200 seconds. For more information, refer to
of
LSPs".
9.
If necessary, define rules for redistributing static, RIP, BGP or OSPF routes. For more information, refer to
Section 13.6.12, "Managing Redistribution
10. Type commit and press Enter to save the changes, or type revert and press Enter to abort.
448
Synopsis:   { level-1-only, level-2-only, level-1-2 }
The IS type for this area: level-1-only, level-2-only or level-1-2. Level-1 routers have
neighbors only on the same area. Level-2-only (backbone) can have neighbors on
different areas. Level-1-2 can have neighbors on any areas. Default is level-1-2.
Synopsis:   { narrow, transition, wide }
Default:   wide
The metric style Type Length Value (TLV) for this area: narrow, transition or wide. Default
is wide.
Synopsis:   { clear, md5 }
Default:   clear
The authorization type for the area password. Default is clear.
Synopsis:   A string 1 to 254 characters long
The area password to be used for transmission of level-1 LSPs.
Synopsis:   { send-only, validate }
Default:   send-only
The authentication option to be used with the area password on SNP PDUs. Default is
send-only.
Synopsis:   { clear, md5 }
Default:   clear
The authorization type for the domain password. Default is clear.
Synopsis:   A string 1 to 254 characters long
The domain password to be used for transmission of level-2 LSPs.
Synopsis:   { send-only, validate }
Default:   send-only
The authentication option to be used with the domain password on SNP PDUs. Default is
send-only.
(NETs)".
Section 13.6.7, "Managing LSP
Section 13.6.10, "Managing LSP Refresh
Section 13.6.8, "Managing SPF
Metrics".
Description
Section 13.6.11, "Managing
Generation".
Intervals".
Calculations".
Section 13.6.9, "Managing the Lifetime