Siemens RUGGEDCOM ROX II User Manual page 474

Hide thumbs Also See for RUGGEDCOM ROX II:
Table of Contents

Advertisement

Chapter 12
Tunneling and VPNs
TUNNEL
NAME
LOCAL IP
----------------------------------------------
tu
192.168.20.10
Section 12.9.4
Adding a 6in4 or 4in6 Tunnel
To add a 6in4 or 4in6 tunnel, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the tunnel by typing:
tunnel [ ip6in4 | ip4in6 ] tunnel name
Where:
• name is the name of the tunnel
3.
Configure the following parameter(s) as required:
Parameter
local-ip
remote-ip
status
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
4.
Section 12.9.5
Deleting a 6in4 or 4in6 Tunnel
To delete a 6in4 or 4in6 tunnel, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the tunnel by typing:
no tunnel [ ip6in4 | ip4in6 ] tunnel name
Where:
• name is the name of the tunnel
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
428
REMOTE IP
STATUS
192.168.20.20
Active
Synopsis:   A string 7 to 15 characters long
The interface upon which the tunnel is created
This parameter is mandatory.
Synopsis:   A string 7 to 15 characters long
Ip address of remote tunnel end
This parameter is mandatory.
Synopsis:   A string
Current status of tunnel
This parameter is mandatory.
Description
Adding a 6in4 or 4in6 Tunnel
RUGGEDCOM ROX II
CLI User Guide

Hide quick links:

Advertisement

Table of Contents
loading