If no egress source ports have been configured, add egress source ports as needed. For more information, refer to
Section 16.1.2.2, "Adding an Egress Source
Section 16.1.2.2
Adding an Egress Source Port
To add an egress source port for port mirroring, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Add the egress source port by typing:
switch port-mirroring egress-src slot port
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 16.1.2.3
Deleting an Egress Source Port
To delete an egress source port for port mirroring, do the following:
1.
Make sure the CLI is in Configuration mode.
2.
Delete the address by typing:
no switch port-mirroring egress-src slot port
Where:
• slot is the name of the module location
• port is the port number (or a list of ports, if aggregated in a port trunk) for the module
Type commit and press Enter to save the changes, or type revert and press Enter to abort.
3.
Section 16.1.3
Managing Ingress Source Ports
This section describes how to configure and manage egress source ports for port mirroring.
CONTENTS
Section 16.1.3.1, "Viewing a List of Ingress Source Ports"
Section 16.1.3.2, "Adding an Ingress Source Port"
Section 16.1.3.3, "Deleting an Ingress Source Port"
Adding an Egress Source Port
Port".
Chapter 16
Traffic Control and Classification
689