Network Discovery and Management
received LLDPDU. A remote system's information is removed from the database when an LLDPDU is received from
it with TTL TLV containing 0 in its information field.
CAUTION!
Security hazard – risk of unauthorized access and/or exploitation. LLDP is not secure by definition.
Avoid enabling LLDP on devices connected to external networks. Siemens recommends using LLDP only
in secure environments operating within a security perimeter.
NOTE
LLDP is implemented to keep a record of only one device per Ethernet port. Therefore, if there are
multiple devices sending LLDP information to a switch port on which LLDP is enabled, information
about the neighbor on that port will change constantly.
CONTENTS
Section 15.1.1, "Configuring LLDP"
Section 15.1.2, "Viewing Global Statistics and Advertised System Information"
Section 15.1.3, "Viewing Statistics for LLDP Neighbors"
Section 15.1.4, "Viewing Statistics for LLDP Ports"
Section 15.1.1
Configuring LLDP
To configure the Link Layer Discovery Protocol (LLDP), do the following:
1.
Make sure the CLI is in Configuration mode.
Navigate to switch » net-discovery » lldp and configure the following parameter(s) as required:
2.
Parameter
enabled
tx-interval { tx-interval }
tx-hold { tx-hold }
reinit-delay { reinit-delay }
tx-delay { tx-delay }
664
Synopsis:   { true, false }
Default:   true
Enables the Link Layer Discovery Protocol (LLDP). Note that LLDP is enabled on a port
when LLDP is enabled globally and along with enabling per port setting in the Port LLDP
Parameters menu.
Synopsis:   A 32-bit signed integer between 5 and 32768
Default:   30
The interval at which Link Layer Discovery Protocol (LLDP) frames are transmitted on
behalf of this LLDP agent.
Synopsis:   A 32-bit signed integer between 2 and 10
Default:   4
The multiplier of the Tx Interval parameter that determines the actual time-to-live
(TTL) value used in an LLDPDU. The actual TTL value can be expressed by the following
formula: TTL = MIN(65535, (Tx Interval * Tx Hold))
Synopsis:   A 32-bit signed integer between 1 and 10
Default:   2
The delay in seconds from when the value of the Admin Status parameter of a particular
port becomes 'Disbled' until re-initialization will be attempted.
Synopsis:   A 32-bit signed integer between 1 and 8192
Default:   2
Description