Honda ACCORD HYBRID 2005 Service Manual page 1657

Hide thumbs Also See for ACCORD HYBRID 2005:
Table of Contents

Advertisement

B l o w e r U n i t C o m p o n e n t
R e p l a c e m e n t
Note these items w h e n overhauling the blower unit:
• The recirculation control motor (A), the blower motor
(B), and the dust and pollen filter (C) can be replaced
w i t h o u t removing the blower unit.
• Before reassembly, make sure the recirculation
control linkage and doors move s m o o t h l y w i t h o u t
binding.
• After reassembly, make sure the recirculation control
motor runs s m o o t h l y (see page 21-85).
E v a p o r a t o r C o r e R e p l a c e m e n t
1. Recover the refrigerant w i t h a recovery/recycling/
charging station (see page 21-103).
2. Remove the bolt, then disconnect the suction line
(A) and the receiver line (B) f r o m the evaporator
core.
6 x 1 . 0 m m
A
9.8 N m
(1.0 k g f m , 7.2 Ibf ft)
3. Remove the blower unit (see page 21-86).
4. Remove the evaporator temperature sensor
(see page 21-78).
5. Remove the harness clip (A), disconnect the
connector (B) f r o m the p o w e r transistor, then
remove the self-tapping screws, and the expansion
valve cover (C).
(cont'd)
21-87

Hide quick links:

Advertisement

Table of Contents
loading