3. Inspect the connector and socket terminals to be sure they are all making good contact.
• If the terminals are bent, loose or corroded, repair them as necessary, and recheck the system.
• If the terminals look OK, go to step 4.
4. With the connectors still disconnected from the under-hood fuse/relay box, make these input tests at the connector(s).
• If any test indicates a problem, find and correct the cause, then recheck the system.
• If all the input tests prove ok, go to step 5.
Cavity
Wire
Test condition
Test: Desired result
Possible cause if result is not obtained
H9
BLK
Under all conditions
Check for continuity to ground:
There should be continuity.
• Poor ground (G601)
• An open in the wire
P1
BRN
Under all conditions
Check for continuity to ground:
There should be continuity.
• Poor ground (G502)
• An open in the wire
E9
BLK
Under all conditions
Check for continuity to ground:
There should be continuity.
• Poor ground (G601)
• An open in the wire
N22
LT BLU
Under all conditions
Check for continuity between
terminal N22 and the climate control
unit B (16P) connector terminal
No. 14:
There should be continuity.
An open in the wire
N22
LT BLU
Climate control unit B
(16P) connector
disconnected
Check for continuity to ground:
There should be no continuity.
Short to ground
J4
GRN
Under all conditions
Check for continuity between
terminal J4 and power w i n d o w
master switch 23P connector
terminal No. 16:
There should be continuity.
An open in the wire
J4
GRN
Power window
master switch 23P
connector
disconnected
Check for continuity to ground:
There should be no continuity.
Short to ground
D11
BLU
Under all conditions
Check for continuity between
terminal D11 and relay control
module I (10P) connector terminal
No. 7:
There should be continuity.
An open in the wire
D11
BLU
Relay control module
I (10P) connector
disconnected
Check for continuity to ground:
There should be no continuity.
Short to ground
X27
LTGRN
Under all conditions
Check for continuity between
terminal X27 and wiper/washer
switch 8P connector terminal No. 4:
There should be continuity.
An open in the wire
X27
LTGRN
Wiper/washer switch
8P connector
disconnected
Check for continuity to ground:
There should be no continuity.
Short to ground
N28
BRN
Under all conditions
Check for continuity between
terminal N28 and gauge assembly
(30P) connector terminal No. 25:
There should be continuity.
An open in the wire
N28
BRN
Gauge control
module 30P
connector
disconnected
Check for continuity to ground:
There should be no continuity.
Short to ground
(cont'd)