D9
Pressure Test
Test results
Related symptoms
Probable cause
Remedy
Discharge
(high)
After stopping A/C compressor,
pressure drops about 196 kPa
Air in system
Recover, evacuate (see page
21-104), and recharge w i t h
pressure
a b n o r m a l l y
(2.0 kgf/cm
2
, 28 psi) quickly, and
then falls gradually.
specified a m o u n t (see page
21-105).
high
Reduced or no a i r f l o w t h r o u g h
• Clogged A/C condenser
• Clean.
A/C condenser.
or radiator fins
• A/C condenser or
radiator fan not
w o r k i n g properly
• Check voltage and fan r p m .
• Check fan direction.
Line to A/C condenser is
Restricted f l o w of
Restricted lines.
excessively hot.
refrigerant in system
Discharge
High and low-pressures are
• Faulty A/C compressor
Replace the A/C compressor.
pressure
balanced soon after stopping A/C
discharge valve
a b n o r m a l l y
compressor. Low side is higher
• Faulty A/C compressor
low
than normal.
seal
Outlet of expansion valve is not
• Faulty expansion valve
• Replace.
frosted, low-pressure gauge
• Moisture in system
• Recover, evacuate, and
indicates v a c u u m .
recharge w i t h specified a m o u n t .
Suction
Expansion valve is not frosted,
• Frozen expansion valve
• Recover, evacuate, and
(low)
and low-pressure line is not cold.
(Moisture in system)
recharge w i t h specified a m o u n t .
pressure
Low-pressure gauge indicates
• Faulty expansion valve
• Replace the expansion valve.
a b n o r m a l l y
v a c u u m .
l o w
Discharge temperature is low, and
the airflow f r o m vents is restricted.
Frozen evaporator
Run the fan w i t h A/C compressor
off, then check evaporator
temperature sensor.
Expansion valve is frosted.
Clogged expansion valve
Clean or replace.
Suction
Low-pressure hose and check
Expansion valve open too
Repair or replace.
pressure
joint are cooler than the
long
abnormally
temperature around evaporator.
high
Suction pressure is lowered w h e n
Excessive refrigerant in
Recover, evacuate, and recharge
A/C condenser is cooled by water.
system
w i t h specified amount.
High and low-pressures are
• Faulty gasket
Replace the A/C compressor.
equalized as soon as the A/C
• Faulty high-pressure
compressor is stopped, and both
valve
gauges fluctuate w h i l e running.
• Foreign particle stuck
in high-pressure valve
Suction and
Reduced airflow t h r o u g h A/C
• Clogged A/C condenser
• Clean.
discharge
condenser.
or radiator fins
• Check voltage and fan r p m .
pressures
• A/C condenser or
• Check fan direction.
a b n o r m a l l y
radiator fan not
high
w o r k i n g properly
Suction and
Low-pressure hose and metal end
Clogged or kinked low-
Repair or replace.
discharge
areas are cooler than evaporator.
pressure hose parts
pressures
a b n o r m a l l y
Temperature around expansion
valve is too low c o m p a r e d w i t h
Clogged high-pressure
line
Repair or replace.
low
that around receiver/dryer.
Refrigerant
A/C compressor clutch is dirty.
A/C compressor shaft
Replace the A/C compressor.
leaks
seal leaking
A/C compressor bolt(s) are dirty.
Leaking around bolt(s)
Tighten bolt(s) or replace A/C
compressor.
A/C compressor gasket is w e t w i t h
oil.
Gasket leaking
Replace the A/C compressor.
21-109