D-Link DXS-3600 Series Reference Manual page 685

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
This command is used to configure the source port of a port monitor session. Use the no form of this
command to remove a port monitor session or remove a source port from the port monitor session.
monitor session SESSION-NUMBER source interface INTERFACE-ID [, | -] [both | rx | tx]
no monitor session SESSION-NUMBER source interface INTERFACE-ID [, | -]
Parameters
session SESSION-NUMBER
interface INTERFACE-ID
,
-
both
rx
tx
Default
No monitor function is configured.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
Both physical ports and port channels are valid as source interfaces of monitor sessions.
For a monitor session, multiple source interfaces can be specified, but only one destination interface can
be specified. An interface cannot be a source interface of one session and destination port of another
session simultaneously. An interface can be configured as destination interface of multiple sessions, but it
can be a source interface of only one session.
If the direction is not specified, both transmitted and received traffic are monitored.
Example
This example shows how to create a port monitor session with session number 1. It assigns a physical
port ethernet1/0/1 as a destination port and three source physical ports (ethernet1/0/2 to ethernet1/0/4)
as monitor source ports.
Switch# configure terminal
Switch(config)# monitor session 1 destination interface ethernet1/0/1
Switch(config)# monitor session 1 source interface ethernet1/0/2-4
Switch(config)#
61-4 monitor session source acl
Specifies the session number for the port monitor session. The valid
range is 1 to 4.
Specifies the source interface for a port monitor session.
(Optional) Specifies the number of interfaces, or separate a range of
interfaces from a previous range. No spaces before and after the
comma.
(Optional) Specifies a range of interfaces. No spaces before and after
the hyphen.
(Optional) Specifies to monitor the packets transmitted and received
on the port.
(Optional) Specifies to monitor the packets received on the port.
(Optional) Specifies to monitor the packets transmitted on the port.
685

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxs-3600-32s

Table of Contents