D-Link DXS-3600 Series Reference Manual page 409

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
This example shows how to configure the shutdown interface eth3/0/1 when an alarm event is detected.
Switch# configure terminal
Switch(config)# interface eth3/0/1
Switch(config-if)# transceiver-monitoring action shutdown alarm#
Switch(config-if)#
27-3 transceiver-monitoring bias-current
This command is used to configure the thresholds of the bias current for a specified port.
Use the no form of the command to remove the configuration.
transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning} VALUE
no transceiver-monitoring bias-current INTERFACE-ID {high | low} {alarm | warning}
Parameters
INTERFACE-ID
high
low
alarm
warning
VALUE
Default
None.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
This configuration is only suitable for SFP/SFP+ port interfaces with optical modules with transceiver-
monitoring.
This command configures the bias-current thresholds on the specified ports. The value will be stored both
in the system and in the SFP/SFP+ transceivers and be converted to the 16-bit format and then rewritten
into the SFP module.
If the SFP module being configured does not support the threshold change, the user-configured threshold
is stored in the system and the displayed value will be the user-configured threshold. If no user-
configured threshold exists, the displayed value will always reflect the factory preset value defined by
vendors.
The no form of this command has the effect to clear the configured threshold stored in the system. It does
not change the threshold stored in the SFP/SFP+ transceivers. Use the no form of the command to
prevent threshold values on newly inserted SFP/SFP+ transceivers from being altered.
Example
This example shows how to configure the bias current high warning threshold as 10.237 on interface
eth3/0/1.
Specifies the interface to modify.
Specifies the high threshold, when the operating parameter rises
above this value. It indicates an abnormal status.
Specifies the low threshold, when the operating parameter falls below
this value, It indicates an abnormal status.
Specifies the threshold for high alarm or low alarm conditions.
Specifies the threshold for high warning or low warning conditions.
Specifies the value of the threshold. This value must be betwee 0 and
131 mA.
409

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxs-3600-32s

Table of Contents