Cable Diagnostics Commands - D-Link DXS-3600 Series Reference Manual

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide

12. Cable Diagnostics Commands

12-1 test cable-diagnostics
This command is used to start the cable diagnostics to test the status and length of copper cables.
test cable-diagnostics interface INTERFACE-ID [,|-]
Parameters
interface INTERFACE-ID
,
-
Default
None.
Command Mode
EXEC Mode.
Command Default Level
Level: 1.
Usage Guideline
The command is available for physical port configuration. Cable Diagnostics can help users to detect
whether the copper Ethernet port has connectivity problems. Use the test cable-diagnostics command
to start the test. The copper port can be in one of the following status:
Open: The cable in the error pair does not have a connection at the specified position.
Short: The cable in the error pair has a short problem at the specified position.
Open or Short: The cable has an open or short problem, but the PHY has no capability to
distinguish between them.
Crosstalk: The cable in the error pair has a crosstalk problem at the specified position.
Shutdown: The remote partner is powered off.
Unknown: The test got an unknown status.
OK: The pair or cable has no error.
No cable: The port does not have any cable connection to the remote partner.
Example
This example shows how to start the cable diagnostics to test the status and length of copper cables.
Switch# test cable-diagnostics interface eth1/1/1
Switch#
12-2 show cable-diagnostics
This command is used to display the test results for the cable diagnostics.
Specifies the interface ID.
(Optional) Specifies a series of interfaces, or separate a range of
interfaces from a previous range. No space before and after the
comma.
(Optional) Specifies a range of interfaces. No space before and after
the hyphen.
257

Advertisement

Table of Contents
loading

This manual is also suitable for:

Dxs-3600-32s