DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Usage Guideline
The link monitoring function counts the number of symbol errors that occur during the specified window
period. This event is generated if the symbol error count is equal to or greater than the specified threshold
for that period.
Example
This example shows how to enable notifying an Ethernet OAM error symbol events on interface eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-symbol
Switch(config-if)#
This example shows how to disable notifying an Ethernet OAM error symbol events on interface eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-symbol
Switch(config-if)#
This example shows how to configure the interface eth1/0/1 Ethernet OAM error symbol monitor
threshold to 100.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-symbol threshold 100
Switch(config-if)#
This example shows how to configure the interface eth1/0/1 Ethernet OAM error symbol monitor window
to 100 deciseconds.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-symbol window 100
Switch(config-if)#
This example shows how to configure the interface eth1/0/1 Ethernet OAM error symbol monitor
threshold to the default value.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-symbol threshold
Switch(config-if)#
36-4 ethernet oam link-monitor error-frame
This command is used to enable notifying the Ethernet OAM error frame event and configure the monitor
threshold and window on the specified port. Use the no command to disable notifying the event or return
the parameters to the default value.
ethernet oam link-monitor error-frame [threshold NUMBER] [window DECISECONDS]
no ethenet-oam link-monitor error-frame [threshold] [window]