D-Link DXS-3600 Series Reference Manual page 461

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Parameters
threshold NUMBER
window DECISECONDS
Default
The Ethernet OAM error frame event shall be notified by default.
The default Ethernet OAM error frame monitor threshold is 1.
The default Ethernet OAM error frame monitor window is 10 deciseconds.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
The link monitoring function counts the number of error frames detected during the specified window
period. This event is generated if the error frame count is equal to or greater than the specified threshold
for that period.
Example
This example shows how to enable notifying an Ethernet OAM error frame event on interface eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame
Switch(config-if)#
This example shows how to disable notifying an Ethernet OAM error frame event on interface eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-frame
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame monitor threshold to
100.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame threshold 100
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame monitor window to
100 deciseconds.
Switch# configure terminal
Specifies the number of frame errors. If the error frames occur in the
specified window and exceeds the threshold value, then an error frame
event is triggered. The range is 0 to 4294967295.
Specifies the amount of time over which the threshold is defined. If the
threshold frame errors occur within the period, an event notification
OAM PDU will be generated with an error frame event TLV, indicating
that the threshold has been crossed in this window. The range is 10 to
600 deciseconds.
461