DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
This example shows how to display the MIP CCM database entries.
Switch# show cfm mip ccm
VID: 10
MAC Address: 00-07-00-00-00-1C
Port: eth1/0/12
VID: 10
MAC Address: 00-07-00-00-00-1E
Port: eth1/0/14
Total: 2
Switch#
14-34
show cfm remote-mep
This command is used to display the remote MEP information.
show cfm remote-mep mepid LOCAL-MEP-ID ma name MA-NAME domain DOMAIN-NAME
[remote-mepid REMOTE-MEPID]
Parameters
mepid MEP-ID
name MA-NAME
domain DOMAIN-NAME
remote-mepid REMOTE-
MEPID
Default
None.
Command Mode
User EXEC or Any Configuration Mode.
Command Default Level
Level: 1.
Usage Guideline
This command is used to display the remote MEP information.
Example
This example shows how to display all the remote MEP information seen by local MEP 1.
Switch# show cfm remote-mep mepid 1 ma name op-ma domain op-domain
Remote MEPID: 2
MAC Address: 00-11-22-33-44-02
Status: OK
Specifies the MEP ID.
Specifies the MA name as the identifier.
Specifies the MD name as the identifier. It is a string type of maximum
length 22.
(Optional) Specifies the remote MEP ID. The range is from 1 to 8191.
RDI: Yes