D-Link DXS-3600 Series Reference Manual page 462

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame window 100
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame monitor window to
default value.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-frame window
Switch(config-if)#
36-5 ethernet oam link-monitor error-frame-seconds
This command is used to enable notifying the Ethernet OAM error frame second event and configure the
monitor threshold and window on the specified port. Use the no command to disable notifying the event
or return the parameters to the default value.
ethernet oam link-monitor error-frame-seconds [threshold NUMBER] [window DECISECONDS]
no ethernet oam link-monitor error-frame-seconds [threshold] [window]
Parameters
threshold NUMBER
window MILLISECONDS
Default
The Ethernet OAM error frame seconds event will be notified by default.
The default Ethernet OAM error frame seconds monitor threshold is 1.
The default Ethernet OAM error frame seconds monitor window is 600 deciseconds.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
The link monitoring function counts the number of error frames that occurred during the specified window
period. This event is generated if the number of error frames is equal to or greater than the specified
threshold for that period. An error frame second is a one second interval wherein at least one frame error
was detected.
Example
This example shows how to enable notifying an Ethernet OAM error frame event on interface eth1/0/1.
Specifies the number of error frames in seconds. If the number of the
error frames occur in the specified window and exceeds the threshold
value, then the frame event is triggered. The range is 1 to 900.
Specifies the amount of time over which the threshold is defined. If
threshold frame errors occur within the period, an event notification
OAM PDU will be generated with an error frame seconds summary
event TLV indicating that the threshold has been crossed in this
window. The range is 100 to 9000 deciseconds.