DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-seconds
Switch(config-if)#
This example shows how to disable notifying an Ethernet OAM error frame event on interface eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-frame-seconds
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame seconds monitor
threshold to 100.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-seconds threshold 100
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame seconds monitor
window to 100 deciseconds.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-seconds window 100
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame seconds monitor
threshold to default value.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-frame-seconds threshold
Switch(config-if)#
36-6 ethernet oam link-monitor error-frame-period
This command is used to enable notifying the Ethernet OAM error frame period event and configure the
monitor threshold and window on the specified port. Use the no command to disable notifying the event
or return the parameters to the default value.
ethernet oam link-monitor error-frame-period [threshold NUMBER] [window NUMBER]
no ethernet oam link-monitor error-frame-period [threshold] [window]
Parameters
threshold NUMBER
window NUMBER
Specifies the number of frame errors that must occur for this event to
be triggered. The range is 0 to 4294967295.
Specifies the number of frames over which the threshold is defined. If
threshold frame errors occur within the period, an event notification
463