D-Link DXS-3600 Series Reference Manual page 464

Dxs-3600 series layer 2/3 managed 10gigabit ethernet switch
Hide thumbs Also See for DXS-3600 Series:
Table of Contents

Advertisement

DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Default
The Ethernet OAM error frame period event will be notified by default.
The default Ethernet OAM error frame period monitor threshold is 1.
The default window value is the number of minimum frame-size frames that can be received in one
second on the underlying physical layer.
Command Mode
Interface Configuration Mode.
Command Default Level
Level: 12.
Usage Guideline
The link monitoring function counts the number of error frames detected during the specified period. The
period is specified by a number of received frames. This event is generated if the error frame count is
greater than or equal to the specified threshold for that period
Example
This example shows how to enable notifying an Ethernet OAM error frame period event on interface
eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-period
Switch(config-if)#
This example shows how to disable notifying and Ethernet OAM error frame period event on interface
eth1/0/1.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# no ethernet oam link-monitor error-frame-period
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame period monitor
threshold to 100.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-period threshold 100
Switch(config-if)#
This example shows how to configure interface eth1/0/1 Ethernet OAM error frame period monitor window
to 1488100 frames.
Switch# configure terminal
Switch(config)# interface eth1/0/1
Switch(config-if)# ethernet oam link-monitor error-frame-period window 1488100
Switch(config-if)#
OAM PDU should be generated with an error frame period event TLV
indicating that the threshold has been crossed in this window. The
lower bound is the number of minimum frame-size frames that can be
received in 100ms on the underlying physical layer. The upper bound
is the number of minimum frame-size frames that can be received in
one minute on the underlying physical layer.