DXS-3600 Series Layer 3 Managed 10Gigabit Ethernet Switch CLI Reference Guide
Parameters
network
start-stop
default
METHOD1 [METHOD2...]
Default
No AAA accounting method is configured.
Command Mode
Global Configuration Mode.
Command Default Level
Level: 15.
Usage Guideline
Use this command to configure the accounting method list for network access fees. For the default
method list to take effect, enable AAA first by using the aaa new-model command. The accounting
system is disabled if the default method list is not configured.
Example
This example shows how to enable accounting of the network access fees using RADIUS and sends the
accounting messages at the start and end time of access:
Switch#configure terminal
Switch(config)#aaa accounting network default start-stop group radius
7-4 aaa accounting system
This command is used to account system events. Use the no command to remove the accounting
method list.
aaa accounting system default start-stop METHOD1 [METHOD2...]
no aaa accounting system default
Parameters
Specifies to perform accounting of network related service requests.
Specifies to send accounting messages at both the start time and the
end time of access. Users are allowed of access the network
regardless of whether the start accounting message enables the
accounting successfully.
Specifies to configure the default method list for network accounting.
Specifies the list of methods that the accounting algorithm tries in the
given sequence. Enter at least one method or enter up to four
methods. The following are keywords that can be used to specify a
method.
group radius – Specifies to use the servers defined by the RADIUS
server host command.
group tacacs+ - Specifies to use the servers defined by the
TACACS+ server host command.
group GROUP-NAME – Specifies to use the server groups defined by
the AAA group server command.
none – Specifies no to perform accounting.