GENERAL
All electrical test have been performed using the
FLUKE 115 MULTIMETER (P/N 529 035 868)
529035868
Results may vary when another multimeter is
used.
PROCEDURES
MAGNETO COVER
Magneto Cover Access
BODY
Refer to
and remove:
– RH side panel
– RH footboard panel.
Magneto Cover Removal
Drain engine oil (refer to
PERIODIC MAINTENANCE PROCEDURES
in the
subsection).
Remove crankshaft position sensor (CPS) and cut
tie raps.
Disconnect the stator connector on the voltage
regulator/rectifier, refer to
ACCESS
in this subsection.
Remove dipstick with O-ring.
vmr2015-116
Section 02 ENGINE, CVT AND GEARBOX
.
ENGINE OIL CHANGE
STATOR CONNECTOR
Subsection 07 (MAGNETO AND STARTER)
vmr2015-030-002_a
1. Dipstick
2. O-ring
3. Crank position sensor (CPS)
Remove magneto cover retaining screws.
vmr2015-030-003_a
1. Magneto cover
2. Retaining screws
Pull out magneto cover.
Magneto Cover Inspection and
Cleaning
Check magneto cover for cracks or other damage.
Replace if necessary.
Clean all metal components in a non- ferrous
metal cleaner. Use
LOCTITE CHISEL (GASKET RE-
MOVER) (P/N 413 708 500)
WARNING
Wear safety glasses and work in a well
ventilated area when working with strong
chemical products.
non-absorbent gloves to protect your hands.
, or suitable equivalent.
Also wear suitable
141