BRP Cam-am Outlander 6x6 DPS 2015 Manual page 10

Table of Contents

Advertisement

4. Apply several drops along the threaded hole
and at the bottom of the hole.
5. Apply several drops on bolt threads.
6. Tighten as required.
Threadlocker Application for Stud
Installation in Blind Holes
1
2
lmr2007-040-005_a
1. On stud threads
2. On threads and in the hole
3. On retaining nut threads
1. Clean threads (stud and hole) with solvent.
2. Apply
LOCTITE 7649 (PRIMER) (P/N 293 800 041)
on threads and allow to dry.
3. Apply 2 or 3 drops of proper strength Loctite
threadlocker on female threads and in hole.
NOTE: To avoid a hydro lock situation, do not ap-
ply too much Loctite.
4. Apply several drops of proper strength Loctite
on stud threads.
5. Install stud.
6. Install cover, part, etc.
7. Apply a few drops of proper strength Loctite on
uncovered stud threads.
8. Install and tighten retaining nut(s) as required.
vmr2013-002
Threadlocker Application for
Pre-Assembled Parts
3
2
A00A3OA
1. Apply here
2. Do not apply
1. Clean bolts and nuts with solvent.
2. Assemble components.
3. Tighten nuts.
4. Apply a few drops of proper strength Loctite on
bolt/nut contact surfaces.
5. Avoid touching metal with tip of flask.
NOTE: For preventive maintenance on exist-
ing equipment, retighten nuts and apply proper
strength Loctite on bolt/nut contact surfaces.
Threadlocker Application for an
Adjustment Screw
A00A3PA
1. Apply here
2. Plunger
1. Adjust screw to proper setting.
2. Apply a few drops of proper strength Loctite
threadlocker on screw/body contact surfaces.
3. Avoid touching metal with tip of flask.
INTRODUCTION
1
2
1
XIX

Advertisement

Table of Contents
loading