vmr2012-023-003_a
1. Diagnostic link connector (DB)
4. Measure the resistance of the CAN resistors as
follows.
REQUIRED TOOL
FLUKE 115
MULTIMETER
(P/N 529 035 868)
CAN RESISTOR TEST
DIAGNOSTIC LINK
CONNECTOR
Pins 1 and 2
NOTE: This tests both the ECM and the Cluster
CAN resistors and wires.
TEST RESULT
READING
Approximately
ECM and CLUSTER CAN wires and
60
resistors good
CAN wire to CLUSTER
Approximately
CAN wire to ECM open
120
CLUSTER CAN resistor open
ECM CAN resistor open
Infinite
CAN wire to DB connector open
(open circuit)
circuit
Multifunction Gauge Removal
1. Remove gauge support.
1.1 Push in on both sides of its leading edge
to disengage it.
1.2 Lift up and pull forward to remove.
vmr2015-137
Subsection 07 (LIGHTS, GAUGE AND ACCESSORIES)
RESISTANCE
Approximately 60
POSSIBLE CAUSE
Section 05 ELECTRICAL SYSTEM
NOTE: There are a total of 6 tabs that retain the
gauge support.
vmr2012-035-001_a
1. Push in and lift up here (both sides)
2. Disconnect gauge connector.
3. From the back of the gauge support, release
the bezel retaining tabs and remove the bezel.
vmr2012-035-002_a
BEZEL RETAINING TABS
4. From back of gauge support, rotate the gauge
clockwise to release it from its support.
Multifunction Gauge Installation
The installationis the reverse of the removal pro-
cedure.
New Multifunction Gauge Registration
(coding)
Whenever the multifunction gauge is replaced,
B.U.D.S. must be used to register it in the ECM.
Simply click Yes when the following message
appears.