TEST CONDITIONS
Load
Time
‡ Required for accurate testing
6. Read amperage on ammeter.
MODEL
All models
NOTE: With a fully charged battery and no electri-
cal loads, specification is less than 7A.
If amperage or voltage is not within specification,
verify magneto and wires. Refer to
AND STARTER
subsection. Replace:
– Voltage regulator if magneto test is within spec-
ifications.
– Magneto if magneto test is not within specifi-
cations.
VOLTAGE REGULATOR (RD)
Voltage Regulator Access
The voltage regulator/rectifier is accessible on the
RH rear side of the vehicle.
vmr2015-134-002_a
Voltage Regulator Continuity Test
Due to internal circuitry, there is no static test
available.
Voltage Regulator Power Test
1. Check voltage at RD1-1.
vmr2015-134
As required to decrease
battery voltage to 12 Vdc
15 seconds

SPECIFICATION

50 ± 5 Amps
MAGNETO
Section 05 ELECTRICAL SYSTEM
Subsection 04 (CHARGING SYSTEM)
+
RD
RD1
-
RD2
vmr2015-134-003_a
TEST CONDITIONS
RD1-1
BACKPROBE
PROBE
RD1-1
BAT2 (-)
2. Connect a battery load tester such as the
ULTRA PRO BATTERY LOAD TESTER (P/N 95260)
3. Start vehicle.
4. Ensure proper test conditions.
TEST CONDITIONS
Battery voltage at idle‡
Engine
Load
Time
‡ Required for accurate testing
5. Measure voltage drop.
+
RD
RD1
-
RD2
vmr2015-134-004_a
BACKPROBE
PROBE
RD1-1
BAT1 (+)
If voltage drop is above specification, locate and
repair damaged connector/wire.
Voltage Regulator Ground Test
1. Check ground at RD1-3.
-
Hot at all times
SPECIFICATION
Battery voltage
NAPA
.
Above 12.6 Vdc
Increase to 4000 RPM
As required to decrease
battery voltage to 12 Vdc
15 seconds
-
SPECIFICATION
Under 0.2 Vdc
437