For more information about event logging, please refer to the
CSMIM/MicroCS Administrator's Guide for UNIX .
Type
Annex
emergency, alert, critical, error, warning, notice, info, debug,
Values
all, none
Default none (disables logging)
Lists
Annex Only, SysLog
syslog_port
routes syslog messages to an asynchronous port where messages are
time and date stamped. You can enter
the network, or a number to indicate the port to which syslog messages
are sent.
Type
Annex
Values
0 or a port number
Default 0
Lists
Annex Only, SysLog
t1_info
contains information about the T1 line supplied by the telephone company.
Type
T1 DS1
Values
0 to 16 characters
Default n/a
Lists
T1_DS1
tcp_keepalive
specifies the length of time a TCP connection must be idle before an Annex
sends keep-alive messages. A keep-alive message contains no data, but
solicits an acknowledgment from the other end of a connection to determine
whether the connection is still active. If the recipient does not acknowledge
the message after eight retries, the Annex drops the connection. You can
use
(Annex Manager's default value) to set the keep-alive time to 120
0
minutes, or you can enter
port_tcp_keepalive
parameter for those individual ports.
Type
Annex
Values
0 to 255 minutes
Default 0 minutes
Lists
Annex Only, Basic Annex
CSMIM/Micro-CS Management Application Guide
to disable the keep-alive mechanism. The
255
and
printer_tcp_keepalive
for syslogging to take place over
0
parameters override values in this
19-91