Chapter 1
Install the Cisco ONS 15310-MA SDH
NTP-H190 Install the Rear Cover
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. For
detailed instructions on how to wear the ESD wristband, refer to the
(ESD) and Grounding
Connect all cables on the backplane before installing the rear cover.
Note
Step 1
Using a #2 Phillips screw driver, remove the six panhead screws from the Electrical Interface Assemblies
(EIAs) located on the A-side and B-side of the backplane
78-19416-01
This procedure explains how to install the rear cover on an ONS 15310-MA
SDH shelf.
#2 Phillips screwdriver
•
1/4-inch nut driver
•
Six 1/4-inch hexagonal standoffs 6-32 x 3.3.25
•
NTP-H158 Install the Electrical Cables, page 1-27
NTP-H160 Install Optical Cables, page 1-29
Required
Onsite
None
Guide.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
Required Tools and Equipment
Cisco ONS Electrostatic Discharge
(Figure
1-10).
1-37