DLP-H180 Change a VCAT Member Service State

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
CTC only permits you to change the state of a non-LCAS member if the new state matches the In Group
Note
VCAT state of the other members, or the new state is an Out of Group VCAT state. The In Group VCAT
state indicates that a member has cross-connects in the unlocked-enabled;
locked-enabled,automaticInService; or locked-enabled,maintenance service states. For non-LCAS
VCAT members, the Out of Group VCAT state is the locked-enabled,disabled service state.
Step 1
In node or network view, click the Circuits tab.
Step 2
Click the VCAT circuit that you want to edit, then click Edit.
Click the Members tab.
Step 3
Select the member that you want to change. To choose multiple members, press Ctrl and click each
Step 4
member.
Step 5
From the Tools menu, choose Set Circuit State.
Note
From the Target Circuit Admin State drop-down list, choose the administrative state:
Step 6
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-70
This task changes a VCAT member service state on the Edit Circuit
window.
None
DLP-H29 Log into CTC, page 16-43
VCAT circuits must exist on the network. See
and VC Low-order Path Tunnels"
As needed
Onsite or remote
Provisioning or higher
You can also change the state for all members listed in the Edit Circuit window using the State
tab. Another alternative is to click the Edit Member button to access the Edit Member Circuit
window for the selected member, and click the State tab.
unlocked—Puts the member cross-connects in the unlocked-enabled service state.
locked, outOfGroup—Puts the member cross-connects in the locked-enabled,disabled service state.
Traffic is not passed on the circuit.
Automatic In Service—Puts the member cross-connects in the
unlocked-disabled,automaticInService service state and suppresses alarms and conditions. When
the connections receive a valid signal, the service state automatically changes to unlocked-enabled.
locked, maintenance—Puts the member cross-connects in the locked-enabled,maintenance service
state. The maintenance state does not interrupt traffic flow; it suppresses alarms and conditions and
allows loopbacks to be performed on the circuit. Use locked, maintenance for circuit testing or to
suppress circuit alarms temporarily. Change the administrative state to unlocked; Automatic In
Service; or locked, outOfGroup when testing is complete.
locked, outOfGroup—(LCAS and Sw-LCAS VCAT only.) Puts VCAT member cross-connects in
the Out-of-Service and Management, Out-of-Group (locked-enabled,outOfGroup) service state.