Ntp-H93 Convert A Point-To-Point To A Linear Adm Manually - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Before You Begin

NTP-H93 Convert a Point-to-Point to a Linear ADM Manually

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
This procedure is service-affecting.
Note
The node being added must be an ONS 15454, ONS 15454 SDH, ONS 15327, ONS 15310-MA SDH, or
ONS 15600.
Note
Optical transmit and receive levels should be in their acceptable range as shown in the specifications
section for each card in
In a point-to-point configuration, two STM-M cards/ports are connected to two STM-M cards/ports on
Note
a second node.
Complete the
Step 1
you are already logged in, continue with
Complete the
Step 2
In node view, display one of the point-to-point node that will connect to the new node.
Step 3
Create a 1+1 protection group for the STM-M cards/ports that will connect to the new node. See the
Step 4
"NTP-H142 Create Protection Groups for ONS 15310-MA SDH" procedure on page 3-10
instructions.
Create DCC terminations on the working STM-M card/port that will connect to the new node. See the
Step 5
"DLP-H52 Provision Section DCC Terminations" task on page
bandwidth is needed for CTC management, complete the
task on page
Step 6
From the View menu, choose Go to Node View to display the new node in node view.
Verify the card installation for the new node as specified in the documentation for that device.
Step 7
Set up timing for the new node as specified in the documentation for that device. If the new node is using
Step 8
line timing, set the working STM-M card/port as the timing source.
Step 9
Turn up the new node as specified in the documentation for that device.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
12-4
This procedure upgrades a point-to-point configuration (two nodes) to a
linear ADM configuration (3 or more nodes) manually, that is, without
using the in-service topology upgrade wizard. Use this procedure if the
wizard is unavailable or you need to back out of the wizard.
None
NTP-H142 Create Protection Groups for ONS 15310-MA SDH,
page 3-10
As needed
Onsite
Provisioning or higher
Table 1-2 on page 1-30
"DLP-H29 Log into CTC" task on page 16-43
"DLP-H163 Check the Network for Alarms and Conditions" task on page
16-71.) In the Create RS-DCC Termination dialog box, set the port state to unlocked.
Chapter 12
for the ONS 15310-MA SDH.
at one of the two point-to-point nodes. If
Step
2.
16-68. (Alternatively, if additional
"DLP-H53 Provision Line DCC Terminations"
Convert Network Configurations
17-56.
for
78-19416-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents