Dlp-H185 Roll Two Cross-Connects On One Optical Circuit Using Automatic Routing - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Chapter 17
DLPs H100 to H199
DLP-H185 Roll Two Cross-Connects on One Optical Circuit Using Automatic
Routing
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
From the View menu, choose Go To Network View.
Step 1
Click the Circuits tab.
Step 2
Click the circuit that has the connections that you want to roll. The circuit must have a DISCOVERED
Step 3
status for you to start a roll.
From the Tools menu, choose Circuits > Roll Circuit.
Step 4
In the Roll Attributes area, complete the following
Step 5
a.
b.
Figure 17-6
Click Next.
Step 6
In the Pivot/Fixed Point 1 window, click the square representing the fixed path of the first connection to
Step 7
be rolled
This path is a fixed point in the cross connection involved in the roll process. The path identifier appears
in the text box below the graphic image. The path that is not selected contains the Roll From path. The
Roll From path is deleted after the roll is completed.
78-19416-01
This task reroutes the network path while maintaining the same source and
destination. This task allows CTC to automatically select a Roll To path.
None
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Provisioning or higher
From the Circuit Roll Mode drop-down list, choose Auto to create an automatic roll or Manual to
create a manual roll.
From the Circuit Type drop-down list, choose Dual to indicate that you want to roll two connections
on the chosen circuit.
Selecting Dual Roll Attributes
(Figure 17-3 on page
(Figure
17-73).
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-6):
17-77