Ntp-H38 Create A Manually Routed E1 Circuit - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Chapter 5
Create Circuits and VC Low-order Path Tunnels
c.
Click Finish. One of the following results occurs, depending on the circuit properties you chose in the
Step 18
Circuit Creation dialog box:
In the Circuits window, verify that the new circuits appear in the circuits list.
Step 19
Complete the
Step 20
test circuit.
Stop. You have completed this procedure.

NTP-H38 Create a Manually Routed E1 Circuit

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
create the circuit. If you are already logged in, continue with
If you want to assign a name to the circuit source and destination ports before you create the circuit,
Step 2
complete the
assigns a circuit name automatically based on circuit type, node name, and sequence number.
Step 3
From the View menu, choose Go to Network View.
Step 4
Click the Circuits tab, then click Create.
Step 5
In the Circuit Creation dialog box, complete the following fields:
78-19416-01
If the provisioned circuit does not reflect the routing and configuration you want, click Back to
verify and change the circuit information. If the circuit needs to be routed to a different path, see the
"NTP-H38 Create a Manually Routed E1 Circuit" procedure on page
If you entered 1 in the Number of Circuits field, CTC creates the circuit.
If you entered more than 1 in the Number of Circuits field and selected Auto-ranged, CTC
automatically creates the number of circuits entered in the Number of Circuits field. If autoranging
cannot complete all the circuits, for example, because sequential ports are unavailable at the source
or destination, a dialog box appears. Set the new source or destination for the remaining circuits,
then click Finish to continue autoranging. After completing the circuits, the Circuits window
appears.
If you entered more than 1 in the Number of Circuits field and did not choose Auto-ranged, the
Circuit Creation dialog box appears for you to create the remaining circuits. Repeat Steps
through
17
for each additional circuit. After completing the circuits, the Circuits window appears.
"NTP-H46 Test Electrical Circuits" procedure on page
This procedure creates a E1 circuit and provisions its circuit route.
None
NTP-H36 Verify Network Turn-Up, page 5-4
As needed
Onsite or remote
Provisioning or higher
"DLP-H29 Log into CTC" task on page 16-43
"DLP-H56 Assign a Name to a Port" task on page
Circuit Type—Choose VC high-order path or VC low-order path. VC high-order path or VC
low-order path cross-connects will carry the E1 circuit across the ONS network.
Number of Circuits—Enter the number of E1 circuits that you want to create. The default is 1.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
Before You Begin
5-9.
5-24. Skip this step if you built a
at a node on the network where you will
Step
2.
16-75. If not, continue with
5
Step
3. CTC
5-9

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents