Required Tools and Equipment
NTP-H157 Install Wires to Alarm, Timing, Craft, LAN, and UDC
Pin Connections
Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Warning
The Alarm, Timing (BITS), Craft, LAN and UDC ports of ONS 15310-MA SDH are intra-building ports.
The CRAFT and LAN ports (rear side) of ONS 15310-MA SDH are intra-building ports to be used for
setup and maintenance purposes by trained personnel and are not connected during normal
operation. The BITS ports are suitable only for connecting to shielded cabling grounded at both ends.
Statement 1085.
The UDC Interface, TL1 Craft Interface, and BITS Interface are not used in OSP installations.
Note
Always use the supplied ESD wristband when working with a powered ONS 15310-MA SDH. For
Caution
detailed instructions on how to wear the ESD wristband, refer to the
(ESD) and Grounding
Complete the
Step 1
page 18-54
Complete the
Step 2
needed. Timing cables are necessary to provision external timing.
Complete the
Step 3
task on page 18-57
the craft interface.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
1-26
This procedure installs alarm, timing, craft (for TL1), LAN (for CTC), and
UDC wires.
Alarm In cable, unshielded cable terminated with a DB-37 connector
Alarm Out cable, unshielded cable terminated with a DB-25 connector
Craft port serial cable, CAT-5 terminated with RJ-45
BITS timing port cable, CAT-3/CAT-5 terminated with DB-9 connector
The cable shield must be wire-wrapped to the GND pin of the wire
Note
wrap adapter.
User data channel (UDC) cable: EIA/TIA-232 port cable, CAT-5
terminated with RJ-45
Management LAN cable, CAT-5 terminated with RJ-45
NTP-H150 Install the Shelf Assembly, page 1-5
As needed
Onsite
None
Guide.
"DLP-H253 Install External Alarm Cables on the ONS 15310-MA SDH" task on
as needed. An alarm cable is necessary to provision external alarms and external controls.
"DLP-H254 Install Timing Cables on the ONS 15310-MA SDH" task on page 18-56
"DLP-H255 Install the Serial Cable for TL1 Craft Interface on the ONS 15310-MA SDH"
as needed. A craft cable is required to use Transaction Language One (TL1) through
Chapter 1
Install the Cisco ONS 15310-MA SDH
Cisco ONS Electrostatic Discharge
as
78-19416-01