DLP-H95 Clear Selected PM Counts

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Pressing the Clear button can mask problems if used incorrectly. This button is commonly used for
Caution
testing purposes. After pressing this button the current bin is marked invalid. Also note that the
Unavailable Seconds (UAS) state is not cleared if you were counting UAS; therefore, this count could
be unreliable when UAS is no longer counting.
In node view, double-click the 15310E-CTX-K9, electrical, or Ethernet card. The card view appears.
Step 1
Note
Click the Performance tab.
Step 2
Click Clear.
Step 3
On the Clear Statistics dialog box, choose one of three options:
Step 4
Click Ok. In the confirmation dialog box, click Yes to clear the selected statistics.
Step 5
View the displayed columns to verify that the selected PM counts have been cleared.
Step 6
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-112
In an ONS 15310-MA SDH node, the 15310E-CTX-K9 card provides optical ports and the
E1_21_E3_DS3_3 and E1_63_E3_DS3_3 cards provide electrical ports. The ONS 15310-MA
SDH supports Ethernet cards.
To clear selected PM Counts for optical ports, click the Optical tab.
To clear selected PM Counts for electrical ports, click the E1, DS3, or E3 tab.
To clear selected PM counts for ML-Series and CE-Series Ethernet cards, click the Ether Ports >
Statistics tabs or the POS Ports > Statistics tabs.
Displayed statistics: Clearing displayed statistics erases from the card and the window all PM
counts associated with the current combination of statistics on the selected port. This means that the
selected time interval, direction, and signal type counts are erased from the card and the window.
This option is available only for electrical and optical ports.
Note
All statistics for port x: Clearing all of the statistics for port x erases from the card and the window
all PM counts associated with all combinations of the statistics on the selected port. This means that
all time intervals, directions, and signal type counts are erased from the card and the window.
All statistics for card: Clearing all of the statistics for the card erases from the card and the window
display all PM counts for all ports.
This task uses the Clear button to clear specified PM counts depending
on the option selected.
None
DLP-H29 Log into CTC, page 16-43