Dlp-H105 Create Ethernet Rmon Alarm Thresholds - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Return to your originating procedure (NTP)
Step 5

DLP-H105 Create Ethernet RMON Alarm Thresholds

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
The CE-100T-8 uses the ONG RMON. The ONG RMON contains the statistics, history, alarms, and
Note
events MIB groups from the standard RMON MIB.
ONG RMON is recommended for the ML-100T-8 card. The standard Cisco IOS RMON is also available.
Note
Double-click the Ethernet card where you want to create the RMON alarm thresholds.
Step 1
Step 2
In card view, click the Provisioning > Ether Ports > RMON Thresholds tabs or the Provisioning >
POS Ports > RMON Thresholds for CE-Series and ML-Series Ethernet cards.
Click Create.
Step 3
The Create Threshold dialog box appears
Figure 17-1
From the Slot drop-down list, choose the appropriate Ethernet card.
Step 4
From the Port drop-down list, choose the applicable port on the Ethernet card you selected.
Step 5
From the Variable drop-down list, choose the variable.
Step 6
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
17-4
This task sets up RMON to allow network management systems to monitor
Ethernet ports.
None
NTP-H148 Verify Card and SFP Installation, page 3-2
As needed
Onsite or remote
Provisioning or higher
(Figure
Creating RMON Thresholds
17-1).
Chapter 17
DLPs H100 to H199
78-19416-01