Chapter 6
Manage Circuits
Complete the
Step 1
network where you want to create the monitor circuit. If you are already logged in, continue with Step 2.
From the View menu, choose Go to Network View.
Step 2
Click the Circuits tab.
Step 3
Choose the bidirectional (two-way) circuit that you want to monitor and click Edit.
Step 4
Verify that the circuit name is no longer than 44 characters. Monitor circuits append a "_MON" to the
Step 5
circuit name. If the name is longer than 44 characters, edit the name in the Name field, then click Apply.
Note
In the Edit Circuit window, click the Monitors tab.
Step 6
The Monitors tab provides ports that you can use to monitor the circuit. The Monitor tab is only available
when the circuit has a DISCOVERED status.
In the Monitors tab, choose the monitor source port. The monitor circuit displays traffic coming into the
Step 7
node at the port you choose.
Step 8
Click Create Monitor Circuit.
In the Circuit Destination section of the Circuit Creation wizard, choose the destination node, slot, port,
Step 9
VC high-order path, VC low-order path, or E1 for the monitored circuit.
Step 10
Click Next.
Step 11
In the Circuit Routing Preferences area, review the monitor circuit information.
Click Finish.
Step 12
In the Edit Circuit window, click Close. The new monitor circuit appears on the Circuits tab.
Step 13
Stop. You have completed this procedure.

NTP-H144 Create a J0 Section Trace

Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
78-19416-01
"DLP-H29 Log into CTC" task on page 16-43
If the circuit name is longer than 44 characters, it appends "_MON" after truncating the circuit
name to 40 characters.
This procedure creates a repeated, fixed-length string of characters used to
monitor interruptions or changes to traffic between nodes.
An ONS 15310-MA SDH 15310E-CTX-K9, E1_63_E3_DS3_3, or
E1_21_E3_DS3_3 card must be installed. J0 section trace applies to
optical ports.
As needed (optional if path trace is set)
Onsite or remote
Provisioning or higher
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
Before You Begin
on an ONS 15310-MA SDH node on the
6-5