Figure 16-21 Store Profile(S) Dialog Box - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Chapter 16
DLPs H1 to H99
A new alarm profile (named in
and appears at the right of the previous profile column in the Alarm Profiles window. You can select it
and drag it to a different position.
Note
The Default profile sets severities to standard Telcordia GR-474-CORE settings. If an alarm has an
Inherited profile, it inherits (copies) its severity from the same alarm's severity at the higher level. For
example, if you choose the Inherited profile from the network view, the severities at the lower levels
(node, card, and port) will be copied from this selection. A card with an Inherited alarm profile copies
the severities used by the node that contains the card. (If you are creating profiles, you can apply these
separately at any level. To do this, refer to the
task on page
Modify (customize) the new alarm profile:
Step 11
In the new alarm profile column, click the alarm severity you want to change in the custom profile.
a.
b.
Choose a severity from the drop-down list.
c.
Repeat Steps
when you view the alarms or conditions after making modifications:
After you have customized the new alarm profile, right-click the profile column to highlight it.
Step 12
Step 13
Click Store.
Step 14
In the Store Profile(s) dialog box, click To Node(s) and go to Step
(Figure
Figure 16-21
a.
Choose the node(s) where you want to save the profile:
78-19416-01
Step
Up to 10 profiles, including the two reserved profiles, Inherited and Default, can be stored in
CTC.
16-100.)
a
and
b
for each severity you want to customize. Refer to the following guidelines
All Critical (CR) or Major (MJ) default or user-defined severity settings are demoted to Minor
(MN) in Non-Service-Affecting (NSA) situations as defined in Telcordia GR-474.
Default severities are used for all alarms and conditions until you create and apply a new profile.
Changing a severity to inherited (I) or unset (U) does not change the severity of the alarm.
16-21).
Store Profile(s) Dialog Box
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
9) is created. This profile duplicates the default profile severities
"DLP-H82 Apply Alarm Profiles to Cards and Nodes"
a
or click To File and go to Step
b
16-97