Dlp-H87 Discontinue Alarm Suppression - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Click Apply.
Step 8
Alarms that apply directly to this port will change appearance as described in
raised on the card will remain raised.) A raised AS-CMD alarm that shows the port as its object will
appear in either alarm window. For example, if you suppressed alarms for Port 1 on the Slot 2 CE 100T-8
card, the alarm object will show "FAC-2-1."
Return to your originating procedure (NTP).
Step 9

DLP-H87 Discontinue Alarm Suppression

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Caution
If multiple CTC sessions are open, discontinuing suppression in one session will discontinue
suppression in all other open sessions.
Step 1
To discontinue alarm suppression for the entire node:
a.
b.
Suppressed alarms will reappear in the Alarms window. (They may have previously been cleared from
the window using the Synchronize button.) The alarms suppressed by user command (AS-CMD)
condition with the System object will be cleared in all views.
Step 2
To discontinue alarm suppression for individual cards:
a.
b.
c.
d.
Suppressed alarms will reappear in the Alarms window. (They may have previously been cleared from
the window using the Synchronize button.) The AS-CMD condition with the slot object (for example,
SLOT-2) will be cleared in all views.
Step 3
Uncheck the Suppress Alarms check box for the ports you no longer want to suppress.
Click Apply.
Step 4
Suppressed alarms will reappear in the Alarms window. (They may have previously been cleared from
the window using the Synchronize button.) The AS-CMD condition with the port object (for example,
FAC-2-1) will be cleared in all views.
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
16-106
This task discontinues alarm suppression and reenables alarm reporting on
a port, card, or node.
None
DLP-H86 Suppress Alarm Reporting, page 16-105
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Provisioning or higher
In node view, click the Provisioning > Alarm Profiles > Alarm Behavior tab.
Uncheck the Suppress Alarms check box.
In the node view, click the Provisioning > Alarm Profiles > Alarm Behavior tabs.
Locate the card that was suppressed in the slot list.
Uncheck the Suppress Alarms column check box for that slot.
Click Apply.
Chapter 16
DLPs H1 to H99
Step
2. (However, alarms
78-19416-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents