Ntp-H188 Create An Ethernet Drop And Continue Circuit - Cisco ONS 15310-MA SDH Procedure Manual

Hide thumbs Also See for ONS 15310-MA SDH:
Table of Contents

Advertisement

Before You Begin

NTP-H188 Create an Ethernet Drop and Continue Circuit

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
If you are already logged in, continue with
To assign a name to the circuit source and destination ports, complete the
Step 2
a Port" task on page
name, and sequence number, continue with
To provision the CE-MR-10 card, complete the
Step 3
page
Step 4
From the View menu, choose Go to Network View.
Click the Circuits tab, then click Create.
Step 5
In the Circuit Creation dialog box, choose the following:
Step 6
Click Next.
Step 7
Define the circuit attributes:
Step 8
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
5-58
This procedure creates a unidirectional Ethernet drop and continue circuit
with multiple drops (circuit destinations) on CE-MR-6 card (ONS
15310-MA SDH only).
Note
The CE-MR-6 card (ONS 15310-MA SDH only) must be installed at the
circuit source and destination nodes.
NTP-H36 Verify Network Turn-Up, page 5-4
As needed
Onsite or remote
Provisioning or higher
"DLP-H29 Log into CTC" task on page
16-75. If you want CTC to assign a name automatically based on circuit type, node
1-19.
Circuit Type—Choose VC_LO_PATH_CIRCUIT.
Number of Circuits—Enter the number of circuits that you want to create. The default is 1. Leave
the default unchanged (1).
Auto-ranged—Unavailable when the Number of Circuits field is 1.
Name—Assign a name to the circuit. The name can be alphanumeric and up to 48 characters,
(including spaces). Circuit names should be 44 characters or less if you want the ability to create
monitor circuits. If you leave the field blank, CTC assigns a default name to the circuit.
Size—Choose VC3.
Bidirectional—Uncheck this to create a unidirectional circuit.
Create cross-connects only (TL1-like)—Check this check box if you want to create one or more
cross-connects to complete a signal path for TL1-generated circuits. If you check this check box,
low-order tunnels and Ethergroup sources and destinations are unavailable.
State—Choose the administrative state to apply to all cross-connects in a circuit:
Unlocked—Puts the circuit cross-connects in the Unlocked-enabled service state.
Locked,disabled—Puts the circuit cross-connects in the Locked-enabled,disabled service state.
Traffic is not passed on the circuit.
Chapter 5
Ethernet drop and continue is supported only on CCAT circuits
(VC3, VC4, VC4-2C, VC4-3C, VC4-4C, VC4-8C, and VC4-16C).
16-43at the node where you will create the circuit.
Step
2.
Step
4.
"NTP-H154 Install the Ethernet Cards" task on
Create Circuits and VC Low-order Path Tunnels
"DLP-H56 Assign a Name to