Chapter 14
Maintain the Node
Click in the Default Value column for the default property you are changing and either choose a value
Step 5
from the drop-down list (when available), or type in the desired new value.
Note
Click Apply (click in the Default Name column to activate the Apply button if it is unavailable). You
Step 6
can modify multiple default values before applying the changes.
A pencil icon will appear next to any default value that will be changed as a result of editing the defaults
file.
Note
Note
If you are modifying node-level defaults, a dialog box appears telling you that applying defaults for node
Step 7
level attributes overrides current provisioning and asks if you want to continue. Click Yes.
If you are modifying the IIOP Listener Port setting, a dialog box appears warning you that the node will
Step 8
reboot and asks if you want to continue. Click Yes.
Stop. You have completed this procedure.

NTP-H138 Import Network Element Defaults

Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
For a list of card and node NE defaults, refer to the "Network Element Defaults" appendix in the
Note
Cisco ONS 15310-MA SDH Reference Manual.
78-19416-01
If you click Reset before you click Apply, all values will return to their original settings.
Changes to most node defaults reprovision the node when you click Apply. Changes made to
card settings using the Defaults Editor do not change the settings for cards that are already
installed or slots that are preprovisioned for cards, but rather, change only cards that are installed
or preprovisioned thereafter. To change settings for installed cards or preprovisioned slots, see
Chapter 9, "Change Port Settings."
Changing some NE defaults can cause CTC disconnection or a reboot of the node in order for
the default to take effect. Before you change a default, view the Side Effects column of the
Defaults editor (right-click a column header and select Show Column > Side Effects) and be
prepared for the occurrence of any side effects listed for that default.
This procedure imports the NE defaults using the NE Defaults editor. The
defaults can either be imported from the CTC software CD (factory
defaults) or from a customized file exported and saved from a node.