Verify that the test set displays a clean signal. If a clean signal does not appear, repeat Steps
Step 8
to make sure that you have configured the test set and cabling correctly.
Inject errors from the test set. Verify that the errors display at the source and destination nodes.
Step 9
Clear the PM counts for the ports that you tested. See the
Step 10
page 16-112
Complete the
Step 11
Perform a BERT for 12 hours or a duration dictated by local testing custom. For information about
Step 12
configuring your test set for BERT, see your test set user guide.
After the BERT is complete, print the results or save them to a disk for future reference. For information
Step 13
about printing or saving test results see your test set user guide.
Complete the
Step 14
circuit ports to their original service state.
Stop. You have completed this procedure.

NTP-H51 Create an Automatically Routed VCAT Circuit

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
Complete the
Step 1
circuit. If you are already logged in, continue with
Complete the following as necessary (you can provision Ethernet or POS ports before or after the VCAT
Step 2
circuit is created):
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2
5-42
STM4 ports—You will test either an STM4c or a multiplexed STM4. If you are testing an STM4c,
configure the test set for an STM4c. If you are testing a multiplexed STM4, configure the test set
for a multiplexed STM4 and choose the DS-3 and/or E1 you will test. For information about
configuring your test set, consult your test set user guide.
for instructions.
"DLP-H55 Path Protection Switching Test" task on page
"DLP-H111 Change a Circuit Service State" task on page 17-15
This procedure creates an automatically routed VCAT circuit. For more
information about VCAT circuits, refer to the "Circuits and Tunnels"
chapter in the Cisco ONS 15310-MA SDH Reference Manual.
ML-100T-8, CE-MR-6, or CE-100T-8 cards must be installed at the nodes
used in the VCAT circuit. For information about the ML-100T-8,
CE-MR-6, or CE-100T-8 cards, refer to the Cisco ONS 15310-CL and
Cisco ONS 15310-MA SDH Ethernet Card Software Feature and
Configuration Guide.
NTP-H36 Verify Network Turn-Up, page 5-4
As needed
Onsite
Provisioning or higher
"DLP-H29 Log into CTC" task on page 16-43
To provision Ethernet ports for CE-100T-8 or CE-MR-6 circuits, complete the
Provision CE-100T-8 and CE-MR-6 Card Ethernet Ports" task on page
To provision POS ports for CE-100T-8 or CE-MR-6 circuits, complete the
CE-100T-8 and CE-MR-6 Card POS Ports" task on page
Chapter 5
Create Circuits and VC Low-order Path Tunnels
"DLP-H95 Clear Selected PM Counts" task on
16-74.
at the node where you will create the VCAT
Step
2.
17-85.
17-87.
2
through
7
to return the circuit and
"DLP-H190
"DLP-H191 Provision
78-19416-01

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents