NTP-H58 Delete Cleared Alarms from Display

Purpose
Tools/Equipment
Prerequisite Procedures None
Required/As Needed
Onsite/Remote
Security Level
Log into a node where you want to delete alarms. See the
Step 1
for instructions. If you are already logged in, continue with Step 2.
To delete cleared node-level alarms:
Step 2
a.
b.
This action removes any cleared ONS 15310-MA SDH alarms from the Alarms display. The rows of
cleared alarms turn white and have a C in their status (ST) column.
ONS 15310-MA SDH Conditions window.
78-19416-01
This procedure deletes Cleared (C) status alarms from the alarms window.
The procedure can be used to delete transient messages from the CTC
History window.
None
As needed
Onsite or remote
Retrieve or higher
In node view, click the Alarms tab and click Synchronize.
Click Delete Cleared Alarms, referring to the following rules:
If the Autodelete Cleared Alarms check box is checked, an alarm disappears from the window
when it is cleared.
If the Autodelete Cleared Alarms check box is not checked, an alarm remains in the window
when it is cleared. The alarm appears white in the window and has a Clear (C) severity. The
alarm can be removed by clicking the Delete Cleared Alarms button.
"DLP-H29 Log into CTC" task on page 16-43
Cisco ONS 15310-MA SDH Procedure Guide, Release 9.1 and Release 9.2