DLP-H38 Create a New User on Multiple Nodes

Purpose
Tools/Equipment
Prerequisite Procedures
Required/As Needed
Onsite/Remote
Security Level
All nodes where you want to add users must be accessible in network view.
Note
From the View menu, choose Go to Network View.
Step 1
Click the Provisioning > Security > Users tabs.
Step 2
In the Security window, click Create.
Step 3
In the Create User dialog box, enter the following:
Step 4
78-19416-01
Password—Type the user password. The password length, by default, is set to a minimum of six and
a maximum of 20 characters. You can configure the default values in CTC node view using the
Provisioning > NE Defaults > Node > security > password Complexity tabs. The minimum length
can be set to eight, ten or twelve characters, and the maximum length to 80 characters. The password
must be a combination of alphanumeric (a-z, A-Z, 0-9) and special (+, #,%) characters, where at
least two characters are nonalphabetic and at least one character is a special character. For TL1
compatibility, the password must have 6 to 10 characters, and the first character must be an alpha
character. The password cannot contain the user name.
Confirm Password—Type the password again to confirm it.
Security Level—Choose a security level for the user: RETRIEVE, MAINTENANCE,
PROVISIONING, or SUPERUSER. Refer to the "Security" chapter in the Cisco ONS 15310-MA
SDH Reference Manual for information about the capabilities provided with each level.
Each security level has a different idle time. The idle time is the length of time that CTC can
Note
remain idle before it locks up and the password must be reentered. Default idle times are:
Retrieve user = unlimited, Maintenance user = 60 minutes, Provisioning user = 30 minutes,
and Superuser = 15 minutes.
This task adds a new user to multiple ONS 15310-MA SDH nodes.
None
DLP-H29 Log into CTC, page 16-43
As needed
Onsite or remote
Superuser only
Name—Type the user name. The name must have a minimum of six and a maximum of
20 alphanumeric characters (a-z, A-Z, 0-9). For TL1 compatibility, the user name must have no more
than 10 characters, and the first character must be an alpha character.