Use The Baseline Button On The Performance Monitoring Screen; Using The Clear Button; Figure 8-6 Clear Button For Clearing Pm Counts - Cisco ONS 15327 User Documentation

Hide thumbs Also See for ONS 15327:
Table of Contents

Advertisement

Chapter 8
Performance Monitoring
Procedure: Use the Baseline Button on the Performance Monitoring Screen
Open the electrical or optical card of choice. Double-click the card graphic in the main (node) view or
Step 1
right-click the card and select Open Card. (Clicking a card once highlights the card only.)
From the card view, click the Performance tab.
Step 2
Click the Baseline button.
Step 3

8.1.6 Using the Clear Button

The Clear button located on the far right of the Performance Monitoring screen clears certain PM counts
depending on the option selected.
screen.
Use caution when pressing the Clear button; improper use can potentially mask problems. This button
Caution
is commonly used for testing purposes such as clearing a count that results in the UAS count
incrementing. The UAS state suppresses counting CVs.
Figure 8-6
June 2002
Figure 8-6
Clear button for clearing PM counts
Using the Performance Monitoring Screen
shows the Clear button on the Performance Monitoring
Cisco ONS 15327 User Documentation, R3.3
Clear button
8-9