6.5 Serial interface

6.5
Serial interface
Information on the serial interface
● Via the serial interface on the device (RJ-11 jack), you can access the CLI of the device
directly via an RS-232 (115200 8N1) connection without assigning an IP address.
● Access to the device is also possible independent of the Ethernet ports.
● To connect the serial interface to the PC, you require a cable with an RJ-11 plug and 9-
pin D-sub female connector. The connecting cable for the serial interface ships with the
device.
Position
Figure 6-12
Figure 6-13
72
Position of the RJ-11 jack on a SCALANCE XR524-8C SCALANCE XR526-8C is
analogous.
Position of the RJ-11 jack on a SCALANCE XR552-12M SCALANCE XR528-6M is
analogous.
Operating Instructions, 09/2018, A5E03275845-12
SCALANCE XR-500