23.2.4 Connecting to CC-Link IE Field Network Ethernet adapter module

(1) When using the connector conversion box
CC-Link IE
Field Network
Ethernet
adapter module
CC-Link IE field network Ethernet
adapter module
Communication
Model
type
NZ2GF-ETB
Ethernet
*3*4
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, wireless LAN adapter (such as NZ2WL-JPA and NZ2WL-JPS), or other system
equipment corresponding to the applicable Ethernet network system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
The use of shielded twisted pair cable (STP) is recommended in environments in which the performance against noise is
required.
For the controllers that allow the connection of a wireless LAN adapter and the setting method of wireless LAN adapters, refer to
the manual of the wireless LAN adapter to be used.
*2
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*3
For the system configuration on the CC-Link IE Field Network module, refer to the CC-Link IE Field Network Ethernet adapter
module manual.
*4
Select [QJ71E71] for [Type] in [Ethernet] of GT Designer3.
For [Ethernet] of GT Designer3, refer to the following.
*5
The number of connectable GOTs for one network is 63 units (at most).
*6
Use sub-version C or later for GT11H-C-37P.
23 - 12
23. ETHERNET CONNECTION
23.2 System Configuration
Connection cable
*1
Connection cable
• 10BASE-T
Shielded twisted pair cable
(STP)
or
Unshielded twisted pair cable
(UTP)
Category 3, 4, and 5
• 100BASE-TX
Shielded twisted pair cable
(STP)
Category 5 and 5e
23.3.3 Ethernet setting
Connector
conversion
box
External cable
Connector
External cable
conversion box
GT14H-C30-42P(3m)
GT16H-CNB-42S
GT14H-C60-42P(6m)
GT14H-C100-42P(10m)
GT11H-C30-37P (3m)
GT16H-CNB-37S
GT11H-C60-37P (6m)
GT11H-C100-37P(10m)
Communication driver
Ethernet(MELSEC),Q17nNC,CRnD-700
GOT
Maximum
Number of
GOT
*6
segment
connectable
model
length
equipment
128 GOTs
(recommend
*2
100m
ed to 16 units
or less)
*5