Connection To Cc-Link Ie Field Network Ethernet Adapter Module - Mitsubishi Electric GT1685 Connection Manual

Got1000 series
Table of Contents

Advertisement

8.2.4

Connection to CC-Link IE Field Network Ethernet Adapter Module

CC-Link IE Field
Network Master/
QCPU
Local module
Connection cable
PLC
*4
1)
CC-Link
IE Field
Model
Network
Cable
name
Master/
model
distance
Local
module
MELSEC-Q
Double-
(Q mode)
shielded
QJ71GF
twisted
C
11-T2
pair
Controller
*4
module
cable
(Q Series)
*1
The destination connected with the twisted pair cable varies with the configuration of the applicable Ethernet network system.
Connect to the Ethernet module, hub, transceiver, or other system equipment corresponding to the applicable Ethernet network
system.
Use cables, connectors, and hubs that meet the IEEE802.3 10BASE-T/100BASE-TX standard.
A cross cable is available for connecting the GOT to the Ethernet module.
*2
When connecting GT16 of the function version A to an equipment that meets the 10BASE (-T/2/5) standard, use the switching
hub and operate in a 10Mbps/100Mbps mixed environment.
For how to check the function version, refer to the following.
*3
A length between a hub and a node.
The maximum distance differs depending on the Ethernet device to be used.
The following shows the number of the connectable nodes when a repeater hub is used.
• 10BASE-T: Max. 4 nodes for a cascade connection (500m)
• 100BASE-TX: Max. 2 nodes for a cascade connection (205m)
When switching hubs are used, the cascade connection between the switching hubs has no logical limit for the number of
cascades.
For the limit, contact the switching hub manufacturer.
*4
Use cables with the following specifications.
Category 5e or higher
Shielded RJ-45
*5
For the system configuration on the CC-Link IE Field Network module side, refer to the following manual.
*6
The number of connectable GOTs for one network is 63 units (at most).
*7
GT14 models compatible with Ethernet connection are only GT1455-QTBDE, GT1450-QMBDE and GT1450-QLBDE.
Connection cable 1)
CC-Link IE
Field Network
Ethernet adapter module
Max.
Communication
Model
Communication
type
name
NZ2G
100m
CC-Link IE
F-
ETB
GT16 User's Manual (Hardware)
Connector
CC-Link IE Field Network Ethernet Adapter Module User's Manual
CC-Link IE
Field Network
Ethernet adapter
module
Connection cable 2)
Connection cable 2)
Cable model
Connection diagram
type
number
Twisted pair cable
• 10BASE-T
Shielded twisted
pair cable (STP) or
unshielded twisted
pair cable (UTP):
Ethernet
Category 3, 4, and
5
• 100BASE-TX
Shielded twisted
pair cable (STP):
Category 5 and 5e
Range
Cable that satisfies the following specifications:
IEEE802.3 1000BASE-T
ANSI/TIA/EIA-568-B(Category 5e)
8. ETHERNET CONNECTION
8.2 System Configuration
Communication driver
Ethernet(MELSEC),
Q17nNC, CRnD-700
GOT
*1
GOT
Number of
connectable
Maximum
equipment
Option
segment
Model
device
*3
length
*2
- (Built
*7
into
GOT)
128 GOTs
(recommen
100m
ded to 16
units or
GT15-
less)
J71E71
-100
8 - 15
1
2
3
4
*6
5
6
7
8

Hide quick links:

Advertisement

Table of Contents
loading