TETRA Commands
17-12 :UNIT Subsystem
The unit subsystem is used to modify the default units used for related parameters.
These changes affect parameters in both commands and responses.
:UNIT:POWer:RX DBM|WATT|VOLTs
:UNIT:POWer:RX?
Description: Sets the receiver unit to dBm or Watts or Volts. If the unit is set to dBm,
Cmd Parameters: DBM|WATT|VOLTs
Query Parameters: NA
Range: DBM|WATT|VOLTs
Default Value: DBM
Default Unit: NA
Example: To set the receiver units to watts:
Front Panel Access: Amplitude, Units, Rx Units
S412E PM
the TETRA Analyzer received power (from FETCh:SIGAnalyzer? or
READ:SIGAnalyzer? or MEASURE:SIGAnalyzer?) and the squelch
setting will be set and queried in dBm. If the unit is set to Watts, the
TETRA Signal Analyzer received power and squelch setting will be set
and queried in fW. If the unit is set to Volts, the TETRA Signal
Analyzer received power and squelch setting will be set and queried in
fV.
:UNIT:POWer:RX WATT
PN: 10580-00319 Rev. N
17-12 :UNIT Subsystem
17-31