Sense] Subsystem - Anritsu LMR Master S412E Programming Manual

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

4-14 [:SENSe] Subsystem

4-14 [:SENSe] Subsystem
The commands in this subsystem relate to device-specific parameters, not signal-oriented
parameters.
[:SENSe]:ACPower:BANDwidth|BWIDth:ADJacent <freq>
[:SENSe]:ACPower:BANDwidth|BWIDth:ADJacent?
Title: ACPR Adjacent Channel Bandwidth
Description: Sets the adjacent channel bandwidth for the ACPR measurement.
Parameter: <freq>
Default Value: 10.35 MHz
Default Unit: Hz
Front Panel Access: Shift-4 (Measure), ACPR, Adj Ch BW
[:SENSe]:ACPower:BANDwidth|BWIDth:MAIN <freq>
[:SENSe]:ACPower:BANDwidth|BWIDth:MAIN?
Title: ACPR Main Channel Bandwidth
Description: Sets the main channel bandwidth for the ACPR measurement.
Parameter: <freq>
Default Value: 10.35 MHz
Default Unit: Hz
Front Panel Access: Shift-4 (Measure), ACPR, Main Ch BW
[:SENSe]:ACPower:BANDwidth|BWIDth:SPACing <freq>
[:SENSe]:ACPower:BANDwidth|BWIDth:SPACing?
Title: ACPR Channel Spacing
Description: Sets the channel spacing for the ACPR measurement.
Parameter: <freq>
Default Value: 10.35 MHz
Default Unit: Hz
Front Panel Access: Shift-4 (Measure), ACPR, Ch Spacing
4-52
PN: 10580-00319 Rev. N
Spectrum Analyzer Commands
S412E PM