Spectrum Analyzer Commands
[:SENSe]:OBWidth:METHod XDB|PERCent
[:SENSe]:OBWidth:METHod?
Title: Occupied Bandwidth Measurement Method
Description: Sets the method for calculating occupied bandwidth. XDB calculates the
Parameter: XDB|PERCent
Parameter Type: <char>
Default Value: PERCent
Related Command: :OBWidth:XDB :OBWidth:PERCent
Front Panel Access: Shift-4 (Measure), OCC BW
[:SENSe]:OBWidth:PERCent <percentage>
[:SENSe]:OBWidth:PERCent?
Title: Occupied Bandwidth Percent of Power
Description: This command sets the percentage of carrier power used to measure the
Parameter: <percentage>
Default Value: 99
Default Unit: %
Range: 0% to 100%
Related Command: :OBWidth:METHod
Front Panel Access: Shift-4 (Measure), OCC BW, %
[:SENSe]:OBWidth:STATe OFF|ON|0|1
[:SENSe]:OBWidth:STATe?
Title: Occupied Bandwidth Measurement State
Description: Sets the state of the occupied bandwidth measurement, ON or OFF.
Parameter: OFF|ON|0|1
Parameter Type: <boolean>
Default Value: OFF
Related Command: :CONFigure:OBWidth
Front Panel Access: Shift-4 (Measure), OCC BW, On/Off
S412E PM
occupied bandwidth based on points a specified number of dB below the
carrier. Issue command [:SENSe]:OBWidth:XDB to set the number of
dB to be used. PERCent calculates the occupied bandwidth based on
points a specified percentage of the carrier power below the carrier.
Issue command [:SENSe]:OBWidth:PERCent to set the percentage to be
used.
occupied bandwidth. This value is used in the measurement if
:SENSe:OBWidth:METHod is set to PERCent.
When using :CONFigure:OBWidth, the state is automatically set to ON.
PN: 10580-00319 Rev. N
4-14 [:SENSe] Subsystem
4-63