P25 Phase 2 Commands
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer <graph type>
:DISPlay[:WINDow]:TRACe<Tr>:FORMat:SIGAnalyzer?
Description: Defines the graph type for the given trace <Tr>. <Tr> is the trace
Cmd Parameters: <graph type>
Query Parameters: NA
Range: LINConstellation|SPECtrum|HISTogram|SUMMary|EYEDiagram
Default Value: Trace 1: Linear Constellation
Default Unit: NA
Example: To set Trace 2 graph type to Eye Diagram:
Related Command: :CONFigure:SIGAnalyzer
Front Panel Access: Measurement, P25p2 Analyzer, Graph Type
S412E PM
number in the range 1 to 4. If no trace number is specified, then the
<Tr> parameter defaults to trace number 1. <Graph Type> is the
graph type to which the specified trace is set, and it must be one of the
following values:
LINConstellation|SPECtrum|HISTogram|SUMMary|EYEDiagram|
PROFile|ACTIve|ADJAcent|BANDplan|SECOndctrl
The query version of this command returns one of the following:
"LINC" if the specified trace graph type is set to linear constellation
"SPEC" if set to Spectrum
"HIST" if set to Histogram
"SUMM" if set to Demodulation Summary
"EYED" if set to Eye Diagram
"PROF" if set to Power Profile
"ACTI" if set to Active Channel Summary
"ADJA" if set to Adjacent Channel Summary
"BAND" if set to Band Plan Summary
"SECO" if set to Backup Control Channel Summary
Please note that this command only works when the current
measurement is set to P25p2 Analyzer.
|PROFile|ACTIve|ADJAcent|BANDplan|SECOndctrl
Trace 2: Spectrum
Trace 3: Histogram
Trace 4: Summary
:DISPlay:TRACe2:FORMat:SIGAnalyzer EYEDiagram
PN: 10580-00319 Rev. N