Anritsu LMR Master S412E Programming Manual page 278

An integrated, handheld multi-function land mobile radio test tool
Hide thumbs Also See for LMR Master S412E:
Table of Contents

Advertisement

9-9 :READ Subsystem
:READ:OTA:C4AGGregation?
Title: Read OTA Carrier Aggregation (4x4 MIMO configuration)
Description: Triggers a new Carrier Aggregation measurement and returns the
Front Panel Access: Measurements, Over-the-Air, Carrier Aggregation
:READ:OTA:CAGGregation?
Title: Read OTA Carrier Aggregation
Description: Triggers a new Carrier Aggregation measurement and returns the
Front Panel Access: Measurements, Over-the-Air, Carrier Aggregation
:READ:PFail?
Title: Read PASS/FAIL
Description: Triggers a new PASS/FAIL measurement and returns the results. It is a
Related Command: MEASure:PFail?
Front Panel Access: Measurements, Pass/Fail Test
9-18
results. OTA Carrier Aggregation must be the active measurement.
This command may not be supported if your instrument is loaded with
older firmware, in which case you may upgrade to the current firmware
version or use the :READ:OTA:CAGGregation? command, instead.
Refer to your instrument User Guide for instructions on updating
firmware.
Data is returned as 70 comma delimited values. The values consist of
5 sets of Component Carrier (CC) data, with each set containing
14 fields (CP, tx1 antenna, tx2 antenna, tx3 antenna, tx4 antenna,
RS Power, RS Delta Power, SS Power, EVM(rms), EVM(pk),
Freq Error, Freq Error (ppm), TAE (nS), and Cell ID). The data is in
sequential CC order. A field with "--" means the data was invalid. An
inactive Component Carrier will show N/A for the entire set of data.
results. The Carrier Aggregation measurement must be the active
measurement (specified by :CONFigure:DEMod CAGGregation). The
current measurement can be queried using the command :CONFigure?
Data is returned as 60 comma delimited values. The values consist of
5 sets of Component Carrier (CC) data with each set containing
12 fields (CP, tx1 antenna, tx2 antenna, RS Power, RS Delta Power,
SS Power, EVM(rms), EVM(PK), Freq Error, Freq Error (ppm),
TAE (nS), and Cell ID). The data is in sequential CC order. A field with
"--" means the data was invalid. An inactive Component Carrier will
show N/A for the entire set of data.
combination of the commands :ABORT; :INITiate; :FETCh:PFail? The
PASS/FAIL measurement must be active. The current measurement
can be queried using :CONFigure?
:CONFigure PFail
FETCh:PFail?
:CONFigure PFail
PN: 10580-00319 Rev. N
LTE Commands
S412E PM

Advertisement

Table of Contents
loading

Table of Contents