14-13 [:SENSe] Subsystem
[:SENSe]:DM:FORMat BS|MS
[:SENSe]:DM:FORMat?
Description: Sets the modulation type. The query will return BS (for Base Station)
Cmd Parameters: BS|MS
Query Parameters: NA
Range: BS|MS
Default Value: BS
Default Unit: NA
Example: To set the modulation type to Mobile Station:
Front Panel Access: Setup, Mod Type
[:SENSe]:DM:PATTern 1031hz|O.153|VOICe|CTRLchan|SILence|IDLE
[:SENSe]:DM:PATTern?
Description: Sets the receiver pattern type. Please note that setting the Rx Pattern
Cmd Parameters: 1031hz|O.153|VOICe|CTRLchan|SILence|IDLE
Query Parameters: NA
Range: 1031hz|O.153|VOICe|CTRLchan|SILence|IDLE
Default Value: 1031hz
Default Unit: NA
Example: To set the modulation type to voice:
Front Panel Access: Setup, Rx Pattern
14-44
and MS (for Mobile Station). Please note that setting the modulation
type will restart the sweep.
:DM:FORMat MS
will restart the sweep.
:DM:PATTern VOICe
PN: 10580-00319 Rev. N
DMR 2 Commands
S412E PM