VNA Commands
Table 5-3.
Trace Header Parameters (Sheet 2 of 8)
Parameter Name
DOMAIN
TRACE_DOMAIN_TYPES
DOMAIN_SETUP
TRACE_MATH_TYPES
TRACE_DISPLAY_TYPES
TRACE_MEMORY_STATE
SMITH_CHART_TYPE
TRACE_SMITH_CHART_TYPES
SMITH_REF_IMPED
TOTAL_CHANNELS
S412E PM
Active Trace domain type, where:
0 is frequency domain,
2 is for distance domain
Domain types for all 4 traces. This uses a bit
mask shift, where the bit shift mask is defined as:
DOMAIN_TYPE_BIT_SHIFT 4
DOMAIN_TYPE_BIT_MASK 0xF
Current Domain Setup. Available Domain setups
are:
Freq = 0, Dist = 2
Trace Math types. This uses a bit mask shift,
where the bit shift mask is defined as:
MATH_TYPE_BIT_SHIFT 4
MATH_TYPE_BIT_MASK 0xF
Available math type are:
None = 0, Subtract = 1, Add = 2, Multiply = 3,
Divide = 4
Trace display types. Available trace types are:
Trace Only = 0, Memory Only = 1,
Trace and Memory = 2
For save/recall purpose.
Where 0 is Off and 1 is On.
Current active trace Smith Chart type. Available
Smith Chart type are:
Normal = 0, Expand 10dB = 1, Expand 20dB = 2,
Expand 30dB = 3, Compress 3dB = 4
Smith Chart type. This uses a bit mask shift,
where the bit shift mask is defined as:
SMITH_CHART_TYPE_BIT_SHIFT 4
SMITH_CHART_TYPE_BIT_MASK 0xF
For available types, refer to
"SMITH_CHART_TYPE".
Reference Impedance. Where:
50 ohm = 0. and 75 ohm = 1
Trace Format. Available trace format are:
Single = 1, Dual = 2, Tri = 3, Quad = 4
PN: 10580-00319 Rev. N
5-10 :Trace Subsystem
Description
5-55

Advertisement

Table of Contents
loading